- Career
- Company
- Contact
- Fast Order
- Greatly reduced
- Jobs
- Legal
-
Products
- Adapter / Converter
- Cables
- Computer cases / mobile racks
- Coolers / fans
- I/O cards / front panel / slot brackets
- Input / Output
- Installation / Maintenance
- Locks / tripods
- Mounts / accessories mobile devices
- Network infrastructure
- New Products
- Offers
- Outlet
- Photovoltaics / Solar
- Power / Energy / Light
- Shipping- / POS-material
- Signal control
- Smart Home
- Service Center
- Theme Worlds
- 9-way socket strip with switch
- Sockets according to DIN 49440, turned by 45°
- Maximum total load 3680 W
- Supply cable: H05VV-F3G1.5mm², length 2m, with angled earthing contact plug CEE7/7
- Strip dimensions: width 19" (482,6mm), height: 1U (45mm), depth 45mm
- Aluminium strip
- Colour: black RAL9004
- 3-socket power strip with switch
- Sockets according to DIN 49440, rotated by 45°
- Maximum total load 2500 W
- Cable: H05VV-F3G1.5mm², length 2m, with straight IEC-C14 plug e.g. for connection to a UPS
- Dimensions strip: Width 10" (254mm), height: 1HE (45mm), Depth 45mm
- Aluminium-power strip
- Colour: Black RAL9004
- 7-socket power strip made of aluminium
- 48.26cm (19") mounting bracket for self-assembly, 5mm thick
- C14 IEC plug for connection to a UPS
- T10A miniature fuse
- Height: 1 U
- Supply cable: 2m, IEC plug
- Max. 10A
- Colour: beige, red
- German assembly instructions
- 19" socket strip 1U
- 8-way Earthing contact socket, max. 16 A
- Cable 3x1.5 mm², 2 m + universal plug CZ-DE max. 16 A
- RAL 9005
- Supplied with: M6 x 16 screws with 2x washers, 2x M6 cage nuts
- Multiple socket strip with switch
- The 19" brackets can be attached to the strip in 8 positions, allowing more customised installation in the cabinet
- Socket outlets in accordance with DIN 49440, rotated by 45°
- Maximum total load 3680 W
- Cable: H05VV-F3G1.5mm², length 2m, with angled earthing contact plug CEE7/7
- Dimensions of strip: Width 19" (482.6mm), height: 1U (45mm), depth 45mm
- Aluminium strip
- Colour: black RAL9004
- 19“ distribution panel 1U, 7 sockets DIN standard
- max. 16A
- Cable 3x1.5mm², 2m long, IEC60309 plug
- surge protection
- 19“ distribution panel 1U, 7 sockets DIN standard
- Color black, RAL 9005
- Supply: 2x screw M6x16 with washer, 2x captive nut M6
- Cable 3x1.5mm², length 2m + universal plug Earthing contact max. 16A
- with indicator lamp
- Color black RAL 9005
- Included item: 2x screws M6x16mm with washers, 2x cage nuts M6
- 14 IEC C13 (female) sockets with ground contacts.
- 45° oriented sockets
- Input voltage 230V
- Maximum load 10A
- 2m 3x15mm power cable with 10A IEC320 C14 plug
- Control power indicator
- Dimensions: Width 48.26cm (19") , Height 1U
- Supplied with: 2x M6x16 screw, 2x plastic washer, 2x cage nut
*The Sensor is an optional accessory. You can use the ATEN PDU without environmental sensors. However, if you want to have complete energy management of your data center with the full use of ATEN solutions, a sensor installation is required.
- Measurement range: – °C (Temperature); 30 – 80 % RH (Humidity)
- Measurement accuracy: +/- 1°C (Temperature); +/- 3 % RH (Humidity)
- Compact design – built in 3m cable
- High sensitivity
- 1x EA1240 Temperature & Humidity sensor
- 1x Sensor mount
- 4x Tie wrap
- 3x Adhesive cable tie holder
Connectors | RJ-11 Male |
Measurement | |
Range | Temperature: 0 - 40°C Humidity: 30– 80% RH |
Accuracy | Temperature: +/- 1°C Humidity: +/- 3 % RH |
Supply Voltage | 5 VDC (Max) |
Current Consumption | 5mA(Max); 2mA(Avg.) |
Environmental | |
Operating Temperature | 0 - 55°C |
Storage Temperature | -20 - 70°C |
Humidity | < 95% RH |
Physical Properties | |
Housing | Plastic |
Weight | 0.06 kg |
Cable Length | 3 m |
- 19" socket strip 1U
- 14-way IEC C13 socket strip, max. 10A
- Cable 3x1.5 mm², 2 m + plug IEC320 C14 max 10 A
- with indicator lamp
- RAL 9005
- Supplied with: M6 x 16 screws with 2x washers, 2x M6 cage nuts
- Space saving -1U rack mount design
- IEC or NEMA outlet models
- Overcurrent Protection
- Aluminum material
- Typical Applications: Servers, Network Devices, Telecom Equipment
- 1x Basic PDU
- 1x Power cord
- 1x User Instructions
Device | PE0212G | ||
Electrical | |||
Nominal Input Voltage | 100-240 VAC | ||
Maximum Input Current | 16A (Max) | ||
Input Frequency | 50-60 Hz | ||
Input Connection | IEC-320 C20 | ||
Input Power | 3840VA(Max) | ||
Outlet Type | (12) IEC 320 C13 | ||
Maximum Output Current (Outlet) | 10A (Max) | ||
Maximum Output Current (Bank) | 16A (Max) | ||
Maximum Output Current (Total) | 16A (Max) | ||
OPD(Overcurrent Protection Device) | Yes | ||
Physical Properties | |||
Dimensions (L x W x H) | 48.80 x 4.40 x 4.50 cm (19.21 x 1.73 x 1.77 in.) | ||
Weight | 0.88 kg ( 1.95 lb ) | ||
Power Cord Length | 10ft(3×1.5mm2) | ||
Environmental | |||
Temperature (Operating / Storage) | 0 – 40? / -20 – 60? *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations. | ||
Elevation (Operating / Storage) | 3000m | ||
Compliance | |||
EMC Verification | CE Class A | ||
Safety Verification | CE, LVD | ||
Note | For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format. |
- 19" socket strip 1U, 8-way according to DIN standard, max. 16A
- Cable 3x1.5mm², 2 m with safety plug
- with varistor Overvoltage protection
- Color black, RAL 9005
Designed with the ultimate flexibility in mind, EA1640 can be placed at an ideal location as a result of the 1.5 m RJ-45 cable coming with it. In addition, it comes with a magnet for easy attachment to metallic surfaces. Rack mount kits are also included for quick installation inside racks.
- A humidity and temperature measuring solution for ATEN PG PDU series
- Precise relative humidity accuracy: ±7.5 % RH, 30 – 70 % RH; ±15 % RH, 15 – 40 % RH, 70 – 90 % RH
- Highly accurate temperature measuring: ±1 °C (Max.), 10 – 40 °C; ±1.5 °C (Max.), –10 – 10 °C, 40 – 75 °C
- Supports up to 8 daisy-chained devices
- Multiple interfaces to broaden applications
- 1 x RJ-45 input port, 1 x RJ-45 output port, and 1x RJ-11input port support connection with PG PDU series and EA1140 / EA1240 / EA1340 environmental sensors
- 1 x terminal block supports EA1440 / EA1441 / EA1442 door sensor and EA1540 capacitive leakage sensor
- Meets flexible installation purposes
- Included 1.5 m RJ-45 cable for ideal location placement
- Contains a magnet for sticking to metallic surfaces
- Included rack mount kits enable quick installation inside racks
- Overload protection prevents overheating of the protected equipment
- LED indicator is visible through the enclosure
- Prevents device malfunctions thanks to early detection in case of overheating / excessive humidity
- Suitable for applications that require precise measuring, such as server rooms, data centers, hospitals, smartfactories, and green offices
1 x Temperature & Humidity Sensor
2 x Rack mount kits
1 x RJ45 Cable
1 x User Instructions
Electrical | |
Environment Sensor Ports | 1 Port Terminal Block for Door Sensor (EA1440/EA1441/EA1442)/ Capacitive Leakage Sensor (EA1540) 1 Port RJ-11 for Original Temperature Sensor (EA1140/EA1240/EA1340) |
Measurement | |
Range | Temperature: –10 to +75 °C Humidity: 0 to 100% |
Accuracy | Temperature: ±1°C (max), 10 to 40 °C ±1.5°C (max), –10 to 10 °C, 40 to 75 °C Humidity: ±7.5% RH, 30–70% RH ±15% RH, 15–40% RH, 70–90% RH |
Power Consumption | DC12V:0.273W:1BTU |
Environmental | |
Humidity (Operating & Storage) | 0 – 80% RH, Non-Condensing |
Temperature (Operating / Storage) | –10 to 75 °C / -20 – 70? |
Physical Properties | |
Dimensions (L x W x H) | 10.44 x 3.57 x 2.14 cm (4.11 x 1.41 x 0.84 in.) |
Weight | 0.05 kg ( 0.11 lb ) |
Cable Length | 1.5M(RJ45+RJ45) round cable |
Housing | Black Polycarbonate |
Compliance | |
EMC Verification | EMC/FCC, Class A |
Safety Verification | By Request |
LEDs | |
LED Indicator | [Solid]: EA1640 is in working mode [Fast Blinking (for 2 minutes)]: EA1640 receives the command “FindMe”. [Slow Blinking (for 10 seconds)]: Over-current protection (OCP) is triggered, and the sensor(s) connected to EA1640 is going to power off. [Slow Blinking]: Firmware upgrade of EA1640 is in progress. |
Aluminum housing helps prolong the units life with rugged casing made of impact-resistant material for maximum durability. Basic 1U PDU can be easily mounted to wall, wooden furniture, or work bench.
- Space saving -1U rack mount design
- IEC outlets
- Surge Protection
- Over-current Protection
- Aluminum material
- Works with data centers, server rooms and telecom equipment
- 1x Basic PDU
- 1x Power cord
- 1x User Instructions
Device | PE0210SG | ||
Electrical | |||
Nominal Input Voltage | 100-240 VAC | ||
Maximum Input Current | 16A (Max) | ||
Input Frequency | 50-60 Hz | ||
Input Connection | For G Plug: IEC-320 C20 | ||
Input Power | 3840VA(Max) | ||
Outlet Type | (10) IEC 320 C13 | ||
Maximum Output Current (Outlet) | 10A (Max) | ||
Maximum Output Current (Bank) | 16A (Max) | ||
Maximum Output Current (Total) | 16A (Max) | ||
OPD(Overcurrent Protection Device) | Yes | ||
Physical Properties | |||
Dimensions (L x W x H) | 48.20 x 4.44 x 4.50 cm (18.98 x 1.75 x 1.77 in.) | ||
Weight | 0.67 kg ( 1.48 lb ) | ||
Power Cord Length | 10ft(3*2.5mm2) | ||
Environmental | |||
Temperature (Operating / Storage) | 0 – 40°C / -20 – 60°C *When the environmental temperature comes close 40 degrees, it is recommended to lower the load to 60% to comply to the safety regulations. | ||
Elevation (Operating / Storage) | 3000m | ||
Note | For some of rack mount products, please note that the standard physical dimensions of WxDxH are expressed using a LxWxH format. |
To monitor the power status of the connected devices, the units feature dual 3-digit 7-segment displays to show the input voltage and output current in real-time. The Basic Metered PDUs provide secure, centralized power usage of data center IT equipment, including servers, storage systems, KVM switches, network devices, to optimize power consumption and asset management.
- Space saving 1U rack mount design
- IEC outlet model
- Overcurrent protection
- Surge protection
- Dual 3-digit 7-segment displays to show current and voltage
- Real-time PDU current monitoring when used in conjunction with the EC1000 Energy Box
- 1x Basic Metered 1U PDU with Surge Protection
- 1x Power Cord
- 1x User Instructions
Device | PE1218SG | ||
Electrical | |||
Nominal Input Voltage | 100-240 VAC | ||
Maximum Input Current | 16A Max | ||
Input Frequency | 50-60 Hz | ||
Input Connection | IEC-320 C20 | ||
Input Power | 3840VA(Max) | ||
Outlet Type | (18) IEC 320 C13 | ||
Maximum Output Current (Outlet) | 10A Max | ||
Maximum Output Current (Bank) | 16A Max | ||
Maximum Output Current (Total) | 16A Max | ||
OPD(Overcurrent Protection Device) | Yes | ||
Physical Properties | |||
Dimensions (L x W x H) | 48.20 x 4.44 x 8.85 cm (18.98 x 1.75 x 3.48 in.) | ||
Weight | 1.30 kg ( 2.86 lb ) | ||
Power Cord Length | 10ft(3×1.5mm2) | ||
Environmental | |||
Temperature (Operating / Storage) | 0 – 40? / -20 – 60? | ||
Elevation (Operating / Storage) | 3000m |
To monitor the power status of the connected devices, the units feature dual 3-digit 7-segment displays to show the input voltage and output current in real-time. The Basic Metered PDUs provide secure, centralized power usage of data center IT equipment, including servers, storage systems, KVM switches, network devices, to optimize power consumption and asset management.
- Space saving 0U rack mount design
- IEC outlet model
- Overcurrent protection
- Surge protection
- Dual 3-digit 7-segment displays to show current and voltage
- Real-time PDU current monitoring when used in conjunction with the EC1000 Energy Box
- 1x Basic Metered 0U PDU with Surge Protection
- 1x L-Shaped Mounting Kit
- 1x User Instructions
Device | PE1324SG | |
Electrical | ||
Nominal Input Voltage | 100-240 VAC | |
Maximum Input Current | 32A Max | |
Input Frequency | 50-60 Hz | |
Input Connection | IEC 60309 32A | |
Input Power | 7680VA(Max) | |
Outlet Type | (24) IEC 320 C13 | |
Maximum Output Current (Outlet) | 10A Max | |
Maximum Output Current (Bank) | 16A Max | |
Maximum Output Current (Total) | 32A Max | |
OPD(Overcurrent Protection Device) | Yes | |
Physical Properties | ||
Dimensions (L x W x H) | 132.71 x 4.44 x 6.00 cm (52.25 x 1.75 x 2.36 in.) | |
Weight | 3.55 kg ( 7.82 lb ) | |
Power Cord Length | 10ft(3×4mm2) | |
Environmental | ||
Temperature (Operating / Storage) | 0 – 40? / -20 – 60? | |
Elevation (Operating / Storage) | 3000m |
- Space saving 1U rack mount design with rear mounting
- 8 IEC outlets, each 10A max.
- 3 digit 7-segment front panel LED shows Current / IP Address
- Remote users can monitor outlet status via web pages on their browsers
- Safe shutdown support
- Separate power for the unit's own power and its power outlets. The user interface is still accessible even when an overload condition trips the devices' circuit breaker
- Remote Access: Remote power control via TCP/IP and a built in 10/100 Ethernet port
- Network Interfaces: TCP/IP, UDP, HTTP, HTTPS, SSL, SMTP, DHCP, NTP, DNS, 10Base-T/100Base-TX, auto sense, Ping
- eco PDU Power Management software eco Sensors
- Supports SNMP Manager V3
- Operation: Local and Remote power outlet control (On, Off, Power Cycle) by individual outlets
- Power-on sequencing users can set the power on sequence and delay time for each port to allow equipment to be turned on in the proper order
- Easy setup and operation via a browser-based user interface
- Multibrowser support (IE, Firefox, Chrome, Safari)
- RTC support to keep the timer running during times of no power.
- Supports up to 8 user and 1 administrator accounts
- Management: Power status measurement at the PDU level
- LED indicators for current and IP address at the PDU device level
- Real-time current, voltage, and kWH displayed in a browsed-based UI for monitoring at the outlet level
- Current and voltage threshold setting
- Naming support for outlets
- User outlet access assignment on an outlet-by-outlet basis.
- Event logging and syslog support
- Upgradeable firmware
- Multilanguage support: English, German, Traditional Chinese, Simplified Chinese, Japanese, French, Spanish, Italian
- Security: Two-level password security
- Strong security features include password protection and advanced encryption technologies 128 bit SSL
- Remote authentication support: RADIUS
- eco Sensors Energy Management Software: Automatic discovery of all PE devices within the same intranet, Remote real-time power measurement and monitoring, Remote real-time power outlet management, Remote real-time environment sensor monitoring, Plotting/Monitoring of all PE devices, Exceed threshold alert through SMTP and Syslog, Power Analysis Report
- Package Contents: 1x PE8108 Power Distribution Unit, 1x Power Cord, 1x Rack Mount Kit, 1x Grounding Wire, 1x Software CD, 1x Quick Start Guide
For the security of your data center, ATEN provides Photo Door sensor probes that work in tandem with the Power Distribution Units, which allows the monitoring of a rack mounted enclosure´s door access, notifying users when a door has been opened. Various conditions can be monitored with alarms according to customizable minimum/maximum settings.
* The Sensor is an optional accessory and you can use the ATEN PDU without the door sensors. However, if you want to have complete security management of your data center with the full use of ATEN solutions, a sensor installation is required.
**Support PE7/PE8/PE9 series only
- The Photo Door Sensor allows the monitoring of a rack mounted enclosure´s door access – notifying users when a door has been opened
- High sensitivity
- Easy operation
Sensing distance | 10 cm |
Operating voltage | 10 – 30 VDC; Ripple < 20 % Peak to Peak |
Current Consumption | 30 mA (max.) |
Output method | NPN & PNP Two Output |
Output status | Normal open NO type |
Output current | 150 mA (max.) |
Leakage current | 0,8 mA (max.) |
Residual voltage | 0,6 mA (max.) |
Protection circuit | Short Circuit and Polarity Protection |
Sensor Response Time | 1 ms (max.) |
Sensitivity adjuster | 270° Trimmer |
Hysteresis | 10 % of Sensing Distance Max |
Emitter | Infrared LED |
Illumination | Sunlight < 10.000 Lux; Lamplight < 5.000 Lux. |
Physical Properties | |
Housing | Plastic |
Package Contents
1x Photo Door Sensor
1x Adjustment Tool
2x Screw
1x Bracket
1x hook-and-loop
The eco PDUs offer secure, centralized and intelligent power management (One -, power off and cycling) for the data center IT equipment (servers, storage systems, KVM switches, network devices, serial data devices, etc.) as well as the ability to monitor the state of the data center environment via sensors.*These PDUs offer remote control of power supply combined with real-time power metering, allowing users to control and monitor the power status of devices connected to the PDUs, either at the PDU device, bank or outlet level, depending on the model, from virtually anyone location via a TCP/IP connection.
The power status of each outlet can be set individually so that users can turn each device on and off. The eco PDU also offers comprehensive power analysis reports, which can be separated by department and location, providing precise measurements of current, voltage, power and watt-hours in a real-time display. Installation and operation are quick and easy by simply plugging cables into the appropriate ports, and users can take advantage of intuitive browser-based configuration and management. The firmware of the eco PDU can be updated via the Internet, i. H. Users can download updates from the ATEN website to ensure their eco PDU is equipped with the latest features and improvements.
The series also supports third-party V3 SNMP manager software and NRGence eco DC (power management - Web GUI). The eco DC simplifies the management of multiple devices by allowing users to configure the eco PDU settings and monitor the power status of the devices connected to the PDU from one user-friendly interface. Along with its features, the PE8324 series is a convenient, reliable and cost-effective solution to remotely manage power access for multiple computer installations and efficiently allocate power resources.
Note:
1. Sensors are optional accessories. A sensor-based installation is required to produce more complete energy efficiency data and charts. The higher the density of sensor installation, the more accurate the data generated will be.
2. eco PDUs are primarily designed for access via the intranet; additional network security protection is recommended for using Internet access.
Scope of delivery:
- 1 x power distribution unit (PDU)
- 1x mounting kit
- 1x CD-ROM< /li>
- 1x instructions for use
In terms of hardware, these PDUs have built-in power-saving relays, a subtype of electromagnetic switches that help operators control large amounts of power, resulting in lower energy consumption compared to models without relays that are unable to save energy.
With five colours (yellow, red, purple, blue and green) of LCD console stickers for users to choose from, distinguishing between power settings and troubleshooting is made easier. In addition, the LCD console is hot-swappable and can be removed, replaced or repaired without having to turn off a mission-critical connected load.
The PG Series is ideal for enterprise servers, network closets and data centres. It is an intelligent power distribution and management solution that supports high-density IT applications while minimising total cost of ownership.
- Each PG PDU has 6 x IEC 60320 C19 and 24 x IEC 60320 C13 outlets in a 0U rack enclosure
- ARM Cortex-A8 processor for flexible control methods via LAN, COM, USB and environmental sensor ports, plus advanced monitoring via LCD console
- Advantageous hardware/network specification
- 1 Gbps and 100 Mbps Ethernet ports
- Automatic ping and reboot
- Remote management protocols: TCP/IP, UDP, HTTP, HTTPS, SSL, DHCP, SMTP, ARP, NTP, DNS, Auto Sense, Ping, SNMP V1&V2&V3, Telnet, Modbus (over TCP/IP), Wi-Fi, 802.11 a/b/g/n network protocols, IPv6, and SMS
- Alerts / Alarms: receives alerts via SNMP, SMTP, SMS1 and syslog
- Scripting: JSON-RPC protocol (Remote Procedure Call) and Python scripting to control specific PDU units (e.g. power on/off, will be included in a future firmware release).
- Security: 2-level account/password login access and IP/MAC filtering, TLS 1.2, SMTP/SMTPS protocols.
- Authentication: LDAP, RADIUS, TACACS+
- Expandable installation
- Allows the connection of up to 64 PDU units with cascading
- Allows a PON port to be connected to an ATEN KN Series KVM-over-IP switch for centralised management of up to 16 cascaded PDUs (To be included in a future firmware release.)
- Energy-efficient relays allow operators to control large amounts of power with lower energy consumption
- Accurate kWh measurement (+/-1%) for better power consumption habits, baselines and initiative tracking
- Ambient sensor port allows RJ-45 connection for connecting or daisy-chaining up to 8 ambient sensors to monitor and manage temperature, humidity, airflow, air pressure differential and leaks
- Real-time LCD warning sends alerts to alert users to unusual power conditions
- An adjustable power cord is integrated into the unit and can be rotated 90 degrees to allow for flexible installation in the rack, resulting in better cable organisation
- Secure locking mechanism prevents the power cord from coming loose from the outlet due to vibration or human error
- Supports ATEN's eco DC (Energy & DCIM Management Web GUI) to monitor power distribution, energy and environmental data from PDUs and connected devices
1 x Power distribution unit
1 x Rack mounting kit
1 x RJ-45 to DB-9 cable
1 x full colour sticker
1 x instruction manual
Device | PG96230G |
Electrical | |
Nominal Input Voltage | 400/230V 3PH (Star) |
Maximum Input Current | 16A Max |
Input Frequency | 50-60 Hz |
Input Connection | IEC-309 16/20A Red 3P+N+PE |
Input Power | 11084VA(Max) |
Outlet Type | IEC 320 C19, IEC 320 C13 |
Nominal Output Voltage | 230 VAC |
Maximum Output Current (Outlet) | C13:10A(Max) C19:16A(Max) |
Breakers | NA |
Metering | Bank level Current, Voltage , PF and KWh Monitoring |
Outlet Switching | Yes |
Environment Sensor Ports | Yes |
Metering Accuracy | 1% |
Physical Properties | |
Dimensions (L x W x H) | 179.00 x 5.60 x 6.80 cm (70.47 x 2.2 x 2.68 in.) |
Weight | 7.36 kg ( 16.21 lb ) |
Power Cord Length | 3m |
Environmental | |
Temperature (Operating / Storage) | 0 – 60° / -20 – 60° |
Humidity (Operating & Storage) | 0 – 80% RH, Non-Condensing |
To monitor the power status of the connected devices, the units feature dual 3-digit 7-segment displays to show the input voltage and output current in real-time. The Basic Metered PDUs provide secure, centralized power usage of data center IT equipment, including servers, storage systems, KVM switches, network devices, to optimize power consumption and asset management.
- Space saving 0U rack mount design
- IEC or NEMA outlet models
- Overcurrent protection
- Surge protection
- Dual 3-digit 7-segment displays to show current and voltage
- Real-time PDU current monitoring when used in conjunction with the EC1000 Energy Box
- 1x Basic Metered 0U PDU with Surge Protection
- 1x Power Cord
- 1x L-Shaped Mounting Kit
- 1x User Instructions
Device | PE1216SG |
Electrical | |
Nominal Input Voltage | 100-240 VAC |
Maximum Input Current | 16A Max |
Input Frequency | 50-60 Hz |
Input Connection | IEC-320 C20 |
Input Power | 3840VA(Max) |
Outlet Type | (16) IEC 320 C13 |
Maximum Output Current (Outlet) | 10A Max |
Maximum Output Current (Bank) | 16A Max |
Maximum Output Current (Total) | 16A Max |
OPD(Overcurrent Protection Device) | Yes |
Physical Properties | |
Dimensions (L x W x H) | 96.71 x 4.44 x 6.00 cm (38.07 x 1.75 x 2.36 in.) |
Weight | 1.30 kg ( 2.86 lb ) |
Power Cord Length | 10ft(3×1.5mm2) |
Environmental | |
Temperature (Operating / Storage) | 0 – 40°C / -20 – 60°C |
Elevation (Operating / Storage) | 3000m |
To monitor the power status of the connected devices, the units feature dual 3-digit 7-segment displays to show the input voltage and output current in real-time. The Basic Metered PDUs provide secure, centralized power usage of data center IT equipment, including servers, storage systems, KVM switches, network devices, to optimize power consumption and asset management.
- Space saving 0U rack mount design
- IEC or NEMA outlet models
- Overcurrent protection
- Surge protection
- Dual 3-digit 7-segment displays to show current and voltage
- Real-time PDU current monitoring when used in conjunction with the EC1000 Energy Box
- 1x Basic Metered 0U PDU with Surge Protection
- 1x Power Cord
- 1x L-Shaped Mounting Kit
- 1x User Instructions
Device | PE1116SG | |
Electrical | ||
Nominal Input Voltage | 100-240 VAC | |
Maximum Input Current | 10A Max | |
Input Frequency | 50-60 Hz | |
Input Connection | IEC-320 C14 | |
Input Power | 2400VA(Max) | |
Outlet Type | (16) IEC 320 C13 | |
Maximum Output Current (Outlet) | 10A Max | |
Maximum Output Current (Bank) | 10A Max | |
Maximum Output Current (Total) | 10A Max | |
OPD(Overcurrent Protection Device) | Yes | |
Physical Properties | ||
Dimensions (L x W x H) | 96.71 x 4.44 x 6.00 cm (38.07 x 1.75 x 2.36 in.) | |
Weight | 1.30 kg ( 2.86 lb ) | |
Power Cord Length | 10ft(3×1.0mm2) | |
Environmental | ||
Temperature (Operating / Storage) | 0 – 40? / -20 – 60? | |
Elevation (Operating / Storage) | 3000m |